spc
   Turkce
ACDC orange 2arrow Voltage Regulators orange 2arrow Regulator Details
spc

pw

  Products

visa

 

45 kVA Three Phase Static Voltage Regulators

AC/DC - Static Voltage Regulators ; are complete electronical voltage regulators which contain no any moving piece inside. Voltage Correction is realised completely under micro processing control via digital technology in ms. No any abrasive part to get through maintenance. It increases the voltage from 220 VAC monophase up to 380 VAC three phase by detecting the change in voltage at first period of the network.20 ms maximum correction is realised. AC/DC Static Regulators ; which are specially selected during manufacturing,are semi-conductors which are resistant to sudden heating and high currents . Through ( thyristör - IGBT ) it responds so fast the loads which require high elevation currents. Static voltage regulators have the ability to open and close each phase independantly., Excessive voltage, over load, hot temperature ve short circuit protection exists...

- 5000 Volt / Second,
- RISC Microprocessor Control,
- Excellent Dynamic,Static Regulation,
- Large Input Voltage Working Range, 130-270 VAC,
- Electronic Protection against overload and short circuit,
- 220 VAC / 380 VAC ; ±% 2,5 Regulation,
- Load level, Output ve Input Display,
- Excessive voltage protection up-down limits.

AC/DC - Static Voltage Regulators ...

logo iso logo ce
pdf Online Catalog

Technical Informations

Information Request

Voltage Regulator Details

15 kVA Static Regulator
22 kVA Static Regulator
30 kVA Static Regulator
45 kVA Static Regulator
60 kVA Static Regulator
75 kVA Static Regulator
90 kVA Static Regulators
100 kVA Static Regulator
120 kVA Static Regulator
150 kVA Static Regulator
180 kVA Static Regulator
200 kVA Static Regulator
250 kVA Static Regulator
300 kVA Static Regulator
400 kVA Static Regulator
500 kVA Static Regulator
600 kVA Static Regulator
800 kVA Static Regulator
1000 kVA Static Regulator
1250 kVA Static Regulator
1500 kVA Static Regulator
1600 kVA Static Regulator
2000 kVA Static Regulator
2500 kVA Static Regulator
3000 kVA Static Regulator
45 kVA Three Phase Static Voltage Regulators Technical Specifications
 
 
   Three Phase Static Voltage Regulators
   Technical Specifications
Input Voltage 380 VAC, 3 Phase + Notr ( Optional 400 VAC, 415 VAC )
Input Voltage Operation Range 250 VAC - 490 VAC ( L-L )
Input Voltage Operation Range 250 VAC - 490 VAC ( L-L )
Operation Frequency 50 Hz  ± 5%
Line Input Protection Over Current thermal fuse and transient over voltage protection
Ani Gerilim ve Darbe Koruma IEEE 587 ( 4500 A, 110 joules )
 REGULATOR OUTPUT
Output Voltage 380 VAC RMS; ±2-5%
Over Load 10 saniye, % 200 yükte
Regulation ( Control ) Speed ~ 5000 Volt / Sec
Responce Time ~ 20 msec.
Output Wave Form Sinusoidal
 DISPLAY & CONTROL PANEL
Display Type 4 x 20 character alphanumeric LCD Screen
Buttons Menu selection and adjustment button with microprocessor
Warning Messages Input Low / Input High, Output Low / Output High, Over Load, Over Temperature
Led ( Input : Green - Output : Green - System Normal : Green - Fault : Red, Other ) ( Optional )
Display Language English
Monitoring Measured Values U, V, W Output Voltages - R, S, T Line Voltages and load percentages
Output Max / Min Protection Limit Adjustable from LCD front panel
 PROTECTIONS
Output Voltage Low : 180 VAC, High : 240 VAC ( Adjustable from Control Panel )
Over Load 10 min. at 125 %, 1 min. at 150 %, 1 sec. at 200 %, 10 msec. at 1000 %
Over Temperature SCR Temperature > 80 °C
By-Pass Manuel By-Pass ( Standard ), Automatic By-Pass ( Optional )
General Protections Short Circuit, Over Load, Over Temperature, Over Voltage, Under Voltage, Peak, Surge, Sag, Spike, Thyristor Failure
 GENERAL
Efficiency > 97% ( Tam yükte )
Operating Technology Micro processing controlled, SCR ( Thyristor ) Tap Changer, Zero Current Switching, Full Regulation at one Cycle, Static ( semiconductor ) structure, Isolation Booster Transformer, No Moving Parts
Protection Level IP 20 ( Standard ) - IP 23 & IP 54 ( Optional )
Cooling Cooling Forced
Run Duration Uninterrupted
Standards EN 50091-1 (Safety) / EN 50091-2 EMC
 ENVIROMENTAL
Operating Temperature Range -10 °C / 50 °C
Storage Temperature Range -20 °C / 70 °C
Relative Humidity % 90 ( Non - Condensing )
Accoustic Level 50 dB ( at 1 Meter )
Operating Heigth 2000 Meter
Note: AC/DC reserves the right to make any changes to data without prior notice. ©2007
AC/DC Electronic Systems Inc.
spc

Home Page  |  UPS Systems  |  Dry Batteries  |  Gel Batteries  |  Voltage Regulators

Battery Chargers  |  Technical Support  |  Power Calculation  |  Site Map  |  Contact

spc

AC/DC Electronic Systems Inc. - TURKEY

Phone: +90 212 320 2007   -   Email: info@acdc.com.tr

spcyears of experience