MODEL |
SAFETECH
S1.1 - 6 kVA |
SAFETECH
S1.1 - 7,5 kVA |
SAFETECH
S1.1 - 10 kVA |
SAFETECH
S1.1 - 15 kVA |
|
Power ( kVA ) |
6 |
7,5 |
10 |
15 |
|
Power ( Cos
j
= 0,7 ) ( kW ) |
4,2 |
5,25 |
7 |
10,5 |
|
INPUT - RECTIFIER UNIT |
|
Voltage |
220 VAC,
1 phase + neutral |
|
Voltage Range |
+ % 15, - % 20 |
|
Current |
35 A |
44 A |
58 A |
88 A |
|
Starting Current |
Inom |
|
Frequency |
50 Hz ± % 5 |
|
OUTPUT - INVERTER UNIT & BYPASS |
|
Power Factor |
0,7 |
|
Voltage |
220 VAC |
|
Voltage Tolerance |
± % 1 |
|
Dynamic Response |
at
load change from 0 - % 100 - 0,voltage decline <
± % 5 |
|
Recovering Time |
Entrance
time of voltage between ± % 1 limit is 40 miliseconds at dynamic load
changing |
|
Frequency |
50 Hz |
|
Frequency Tolerance |
While
synchronous to mains ± % 1 - in battery mode ± % 0,2 |
|
Current |
19 A |
24 A |
32 A |
48 A |
|
Max. Fuse Current (A)-max. |
16 A |
16 A |
16 A |
20 A |
|
Output Wave form |
Sinüzoidal |
|
Total Harmonic Distortion |
< % 3 |
|
Capacity for Non-linear load |
until % 100 load |
|
Crest Factor |
3 : 1 |
|
Overload Capacity |
at % 100-125 load 2,5
minutes |
|
at % 125-150 loads 1
minute |
|
at % 150-200 loads 2
seconds |
|
at load > % 200 immediate
Bypass |
|
Short Circuit proof |
Elektronic short circuit
protection, short circuit current % 200 x
Inom |
|
Static & Service Bypass |
Standard |
|
Bypass Voltage & Tolerance |
220 VAC,
± % 10 / 1 phase + Neutral |
|
Bypass Frequency |
50 Hz |
|
Bypass Power ( kVA ) |
6 |
7,5 |
10 |
15 |
|
Bypass Overload Capacity |
% 150 |
|
Transfer Time |
uninterruptible |
|
BATTERY |
|
Number of Batteries |
20 |
|
Battery Type |
Sealed
Lead Acid Battery, Maintenance Free |
|
Back up Time ( Full Load ) |
9 minutes. |
5 minutes. |
6 minutes. |
5 minutes. |
|
Float Charging Voltage |
270 VDC |
|
End of Discharge
Voltage |
200 VDC |
|
Battery Placement |
Internal |
Extra Cabin |
|
Battery Charge Current |
2 amphere
- extra charger can be used for long back up time |
|
Charging Time |
in 8 hours to % 90 capacity
after complete discharge |
Battery Environment Temperature (
required ) |
17 ~ 25 °C |
|
Battery Protection |
Automatic Fuse |
|
Battery Test |
Standard |
|
INDICATOR &
CONTROL PANEL |
|
Type |
2 Lines x
16 Characters LCD Screen with lightining back plan |
|
Control Panel |
Touch
sensible buttons |
|
Measurements & Indicators |
RMS %
Load, Max. % Load, Crest Factor, Input Voltage, Currents, Output Voltage,
Frequency, Bypass Voltage, Frequency, Battery Voltage, Battery Current,
Synchronization, Rectifier, Inverter, Battery cabin and Environment
Temperature (Optional), All indicators and Status Messages |
|
LED |
Mains 1,
Mains 2, Rectifier, Inverter, Load, Bypass and Battery |
|
Indicator Language |
Turkish
and English |
|
COMMUNICATION |
|
Interface |
Standard DB 9 Port |
|
Protocol |
Intelligent RS232 ( Standard ), SNMP ( Optional ) |
|
Software |
Software
support Windows 95/98/NT/2000/XP, Linux and Novell |
|
GENERAL |
|
Efficiency Total at %100 |
% 85 |
|
Noise Level |
< 45 dBA |
|
EMC Emissions |
Class A
according to EN 50091-2 |
|
Operating Temperature |
0
°C ~ 40 °C |
|
Stroge Temerature |
-20
°C ~ +70 °C |
|
Humidity |
Maximum
% 20-90 |
|
Protection Degree |
IP20 (
According to IEC 529/EN 60529 ) |
|
Equipment Colour |
RAL 7035 |
|
Type of Cooling |
Cooling
forced with fan |
|
Installation Height |
< 1000
meters (from sea level), in nominal load |
|
Size (mm), W x D x H |
315 x 810
x 765 |
|
Weight, ( kg ) |
/ |
/ |
/ |
/ |