            ONLINE UPS SYSTEMS :

 

Millennium 1.1 Series UPS Systems : 6 kVA - 7,5 kVA - 10 kVA - 15 kVA

 
 
 
Genel Bilgiler

             

Millennium 1.1 Series On Line UPS

Millennium 1 phase Series UPS Systems :
1 kVA - 2 kVA - 3 kVA - 6 kVA
;

Millennium 1.1 Series UPS Systems ;

Mikroprocessor control guarrantees high reliability, Smart RS 232 Communication Port with Free Download Software, Equipped with the comprehensive self-protection design, Intelligent SNMP slot to allow communication among various operation systems and remote monitoring of the UPS, Audible Alarm Mute , Cold Start Function , Auto self-testing system while turning on the UPS , Maintenance Bypass Switch ( Available for Millenium 6 kVA ), The Widest Input Voltage Range ( Low Derating Reguired ), Expandable back up time...

2 year warranty,

Technical Specifications

  MODEL

MILLENNIUM
1.1  - 1 kVA
MILLENNIUM
1.1 - 2 kVA
MILLENNIUM
1.1 - 3 kVA
MILLENNIUM
1.1 - 6 kVA

  Power ( VA )

 1000 2000 3000 6000
  Power ( Cos j  = 0,7 ) ( Watt )  700 1400 2100 4200

  INPUT

  Voltage

220 VAC

  Voltage Range 118 - 300 VAC 176 - 276 VAC
  Frequency  50 Hz
  Frequency Range 46 ~ 54 Hz 46.5 ~ 55 Hz

  OUTPUT

  Voltage 220 VAC
  Voltage Regulation ± % 1 ± % 3
  Output Frequency 50 Hz ± % 0.2 ( Akü Modu ) 50 Hz ± % 0.2
  Output Waveform

Pure Sinewave

  HARMONIC DISTORTION

  Linear Load ≤% 3 ≤% 4 ≤% 4 ≤% 4
  Non-Linear Load

≤% 6

≤% 7 ≤% 7 ≤% 8
  CREST FACTOR
  Current Crest Ratio

3 : 1

  BATTERY
  Type

Sealed Lead Acid Battery, Maintenance Free

  Number of Batteries

3

8 8 20
  Back up Time ( Full Load )

8 minutes

10 minutes 6 minutes 10 minutes

  AUDIBLE ALARM

  Battery Mode

Sounding Every 4 Seconds 

  Battery Low

Sounding Every Seconds 

  Overload

Sounding Twice Every Seconds

Sounding Every Seconds

  Fault

Continuously Sounding

  TRANSFER TIME
  AC to AC

Zero

  Inverter to Bypass

2,5 ms ( Typical )

  ENVIRONMENT
  Operating Temperature

0 °C - 40 °C     ;     32 °F - 104 °F

  Relative Humudity

% 20 - 90 ( Non - Condensing )

  Noise Level ( at 1 meter ) < 45 dB < 50 dB < 50 dB < 55 dB

  GENERAL

  Efficiency Total at %

> % 87

> % 90

  Indicators ( Status )

Load Level  /  Battery Level  /  Battery Mode  /  AC Mode  /  Bypass  /  Fault

  Type of Cooling

Cooling forced with fan

  Size (mm), W x H x D

145 x 220 x 400

192 x 340 x 460

192 x 340 x 460 260 x 717 x 570
  Weight, ( Net weight )

13 kgs

32 kgs 33 kgs 84 kgs